homepage Product center Atlas Air Compressor Bolet air compressor Air post-treatment equipment Air compressor application list Air compressor encyclopedia About us Contact us

Atlas Copco air compressor 0512-62910301

Company headquarters: Suzhou high-tech Zone Liangang Road Shanghai Marketing: Baosheng Road, Songjiang District, Shanghai Factory address: Changjiang Road, Xinwu District, Wuxi City Telephone consultation, regional personnel will be arranged to contact

Summer is coming | what are the causes of high temperature failure of air compressor and the solutions?

作者: Bolet air compressor 时间:2023.05.15 Page views: 1332

With the gradual increase in weather temperatures, representing the largest summer in the general machinery industry has arrived。Before this, our after-sales service engineers have carried out a round of inspection of the air compressor phenomenon in order to avoid the high temperature phenomenon of the air compressor and provide users with a response suitable for each factory。Today Xiaobian has also sorted out for youAir compressor high temperatureSome common causes of the scene and solutions。

1, the compressor used inferior or expired lubricating oil

Failure cause: poor oil, or the use of expired lubricating oil will cause the machine to accumulate carbon or increase wear during the process of rotation, resulting inAir compressor high temperature

Solution: Use the original authentic oil or meet the requirements。

2. The filter is blocked

Failure cause: After the medium pressure air compressor is used for a period of time, there will be impurities in the filter, causing blockage。

Solution: Clean or replace the filter regularly。


3, radiator failure or abnormal operation

The cause of the failure: the radiator is not cleaned for a long time and covered with dust and dirt, the operation is not normal, or the radiator fails to cause the high temperature of the air compressor。

Solution: Clean the radiator and replace the radiator。

4, there are heat sources around the compressor

Solution: Remove the heat source, or remove the compressor。

5. The medium pressure air compressor is not ventilated

The cause of the failure: the compressor will produce a lot of heat in the process of use, the ventilation effect is poor, and the generated heat cannot be discharged, which will affect the equipment and lead to high temperature of the air compressor。

Solution: Place the device in a ventilated location。

The above content is composed ofAtlas Bolet compressorSmall series collection。

Previous post:Why do air compressors do energy efficiency tests?
Next post:Assembly method of air compressor coupling
homepage Atlas Air Compressor Bolet air compressor Air post-treatment equipment Atlas Copco Shanghai Bolet compressor Air compressor maintenance
" class="hidden">仁寿在线